Entrance Surface Air Kerma (ESAK) in Adult Posteroanterior (PA) Chest Radiography: An Exploratory Analysis
DOI:
https://doi.org/10.32734/jotp.v8i1.24603Keywords:
Chest radiography, dose optimization, ESAK, patient dose, radiation protectionAbstract
This study estimated Entrance Surface Air Kerma (ESAK) for adult posteroanterior (PA) chest radiography and described ESAK patterns in relation to selected technical parameters and patient characteristics as an initial facility-level baseline. A descriptive–exploratory observational study was conducted in 10 adult patients using a Siemens digital radiography system equipped with Automatic Exposure Control (AEC). ESAK was estimated from X-ray tube output obtained from acceptance/constancy testing and combined with routinely recorded exposure parameters. Incident air kerma (INAK) was calculated first and then converted to ESAK using a backscatter factor assumed to be constant at 1.35. All examinations were performed at 125 kVp with a fixed source-to-image distance (SID) of 180 cm. Focus-to-skin distance (FSD) was not recorded directly and was estimated from SID and the recorded chest thickness. ESAK ranged from 0.09 to 0.17 mGy (mean, 0.13 mGy), and all values were below the BAPETEN optimization reference level of 0.2 mGy. In this limited sample, graphical patterns indicated that ESAK increased with mAs and body weight and decreased with increasing FSD. These findings are preliminary and require confirmation in a larger cohort; however, they may serve as a temporary local baseline for internal dose auditing and to inform the design of subsequent dose optimization studies.
Downloads
References
[1] S. Prabhu, D. K. Naveen, S. Bangera, and S. Bhat B, “Production of X-rays using X-ray tube,” Journal of Physics: Conference Series, vol. 1712, pp. 1-12, 2020.
[2] I. I. Suliman, “Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman,” J Digit Imaging, vol. 33, no.1, pp. 64-70, 2020. doi: 10.1007/s10278-019-00199-y.
[3] V. Tsapaki, “Radiation dose optimization in diagnostic and interventional radiology: Current issues and future perspectives,” Physica Medica, vol. 79, pp. 16–21, 2020. doi: 10.1016/j.ejmp.2020.09.015.
[4] Badan Pengawas Tenaga Nuklir (BAPETEN), Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 8 Tahun 2011 tentang Keselamatan Radiasi dalam Penggunaan Pesawat Sinar X Radiologi Diagnostik dan Intervensional. Jakarta, Indonesia: BAPETEN, 2011. [Online]. Available: https://jdih.bapeten.go.id/unggah/dokumen/peraturan/81-full.pdf. [Accessed: Jan. 7, 2026].
[5] E. Vañó, D. L. Miller, C. J. Martin, M. M. Rehani, K. Kang, M. Rosenstein, P. Ortiz-López, S. Mattsson, R. Padovani, and A. Rogers, “Diagnostic Reference Levels in Medical Imaging, ICRP Publication 135,” ICRP, vol. 46, no. 1, pp. 1–144, 2017. doi: 10.1177/0146645317717209.
[6] International Atomic Energy Agency (IAEA), Dose Management Systems From Setting up to Quality Assurance,” IAEA Human Health Series No. 49, Vienna, Austria: IAEA, 2025. [Online]. https://www-pub.iaea.org/MTCD/publications/PDF/p15847-PUB2112_web.pdf. [Accessed: Jan. 7, 2026].
[7] I. I. Suliman, “An approach for the online determination of Entrance Surface Air Kerma (ESAK) from Kerma Area product (PKA) in digital radiology,” Phys Eng Sci Med, vol. 45, pp. 1055-1061, 2022. doi: 10.1007/s13246-022-01167-7.
[8] C. Kaushik, I. S. Sandhu, A. K. Srivastava, and M. Chitkara, “Estimation of entrance surface air kerma in digital radiographic examinations,” Radiation Protection Dosimetry, vol. 193, no. 1, pp. 16–23, 2021. doi:10.1093/rpd/ncab018.
[9] A. Promduang, N. Pongnapang, N. Ritlumlert, S. Tangruangkiat, and M. Phonlakrai, “A study of entrance surface air kerma for patients undergoing chest and abdomen from digital radiography at Chulabhorn Hospital,” Journal of Health Science and Medical Research, vol. 37, no. 1, pp. 51–60, 2019.
[10] A. O. Masoud, M. J. Kumwenda, S. K. Salum, A. M. Jusabani, and K. O. Amour, “Radiation Doses to Patients Undergoing Common X-ray Examinations from Selected Hospitals in Dar es Salaam and Zanzibar, Tanzania,” Tanzania Journal of Science, vol. 50, no. 3, pp. 569–579, 2024, doi:10.4314/tjs.v50i3.12.
[11] H. D. R. Raharja, N. I. S. Supit, and U. N. Haposan, “Estimasi dan audit dosis radiasi pasien pada pemeriksaan radiografi konvensional toraks PA dengan teknik high kVp,” Prosiding Seminar Si-INTAN, Vol. 2, No. 1, 2022, pp. 63-68, doi:10.53862/SSI.v2.072022.010.
[12] A. Creeden and M. Curtis, “Optimising default radiographic exposure factors using deviation index,” Radiography, vol. 26, no. 4, pp. 308–313, 2020. doi:10.1016/j.radi.2020.02.009.
[13] R. Putri, D. Milvita, and I. B. G. P. Pratama, “Analisis korelasi nilai entrance surface air kerma (ESAK) terhadap massa tubuh, usia, dan faktor eksposi pada pasien pemeriksaan radiografi umum di RSUP Dr. M. Djamil Padang,” Jurnal Fisika Unand, vol. 14, no. 4, pp. 413–420, 2025. doi: 10.25077/jfu.14.4.413-420.2025
[14] S. I. Sari, D. Milvita, R. Fardela, I. B. G. P. Pratama, and A. Oktavia, “Analisis korelasi umur, massa tubuh dan faktor eksposi terhadap Entrance Surface Air Kerma pada pemeriksaan thorax di Rumah Sakit Universitas Andalas,” Jurnal Fisika Unand, vol. 13, no. 5, pp. 602–609, 2024. doi:10.25077/jfu.13.5.602-609.2024.
[15] P. I. Wulandari, N. P. R. Jeniyanthi, I. M. L. Prasetya, I. P. A. Susanta, I. P. E. Juliantara, and A. A. Diartama, “Evaluasi dosis radiasi pada pemeriksaan radiografi thorax,” PREPOTIF: Jurnal Kesehatan Masyarakat, vol. 7, no. 3, pp. 16325–16330, 2023. doi: 10.31004/prepotif.v7i3.19824.
[16] S. Lewis, T. Pieterse, and H. Lawrence, “Retrospective evaluation of exposure indicators: A pilot study of exposure technique in digital radiography,” Journal of Medical Radiation Sciences, vol. 66, pp. 38–43, 2019.
[17] H. Park, J. Kim, E.-J. Kang, Y. Kim, H. Jo, J.-H. Heo, W. Yang, and Y. Yoon, “Feasibility of new patient dose management tool in digital radiography: Using clinical exposure index data of mobile chest radiography in a large university hospital,” Heliyon, vol. 9, no. 10, 2023. doi: 10.1016/j.heliyon.2023.e20760.
[18] European Commission, European Guidance on Estimating Population Doses from Medical X-Ray Procedures, “Radiation Protection No. 154,” Luxembourg: Directorate-General for Energy and Transport, Directorate H — Nuclear Energy, Unit H.4 — Radiation Protection, 2008. [Online]. https://www.sprmn.pt/pdf/RP154.pdf. [Accessed: Jan. 7, 2026].
[19] Badan Pengawas Tenaga Nuklir (BAPETEN), Lampiran Keputusan Kepala Badan Pengawas Tenaga Nuklir Nomor 1812 Tahun 2025 tentang Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level) untuk Pemeriksaan Pasien dengan Pesawat Sinar-X Radiografi Umum, CT-Scan, Fluoroskopi Intervensional, dan Pemeriksaan Kedokteran Nuklir Diagnostik, Jakarta, Indonesia: BAPETEN, 2025. [Online]. https://bapeten.go.id/upload/78/84a27d22df-1812lampiransurat-keputusan-kepala-tentang-tpdi-2025.pdf. [Accessed: Jan. 7, 2026].
[20] International Atomic Energy Agency (IAEA), Dosimetry in Diagnostic Radiology: An International Code of Practice, IAEA Technical Reports Series No. 457, Vienna, Austria: IAEA, 2007. [Online]. https://www-pub.iaea.org/MTCD/Publications/PDF/TRS457_web.pdf. [Accessed: Jan. 7, 2026].
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Journal of Technomaterial Physics

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.







